Healthcare & Pharmaceutical TAB Specialists
AABC / CAABC Certified

Keeping critical healthcare spaces safe and compliant.

Independent testing and balancing for hospitals, pharmacies and laboratories across Ontario and the Greater Toronto Area.

Air distribution ductwork and mechanical services inside a large facility.

25M+Sq. ft. healthcareBalanced across hospitals, clinics, and pharma facilities.

80+ yearsCombined experienceSenior TAB technologists and field specialists.

100%Independent TABTAB and audit focused firm.

Testing, Adjusting & Balancing Services

Comprehensive TAB and commissioning support for healthcare, pharmaceutical, laboratory, and complex commercial projects across Ontario and the GTA.

Hydronic pumps, insulated piping and pressure gauges.

Air Balancing

Supply, return, exhaust, and relief air balancing to AABC procedures, with a focus on critical healthcare environments.

  • OR, ICU, NICU & diagnostic spaces
  • Isolation room pressurization & ACH verification
  • VAV, CAV, and induction systems

Hydronic Balancing

Precise balancing for chilled water, hot water, glycol, and condenser water systems to optimize ∆T and system performance.

  • Primary/secondary and decoupled systems
  • Pump curves, flows, and energy optimization
  • OR and critical reheat coil verification

Duct Leakage & Investigative TAB

SMACNA duct leakage testing and investigative TAB for persistent pressure, comfort, or IAQ issues in critical areas.

  • SMACNA CL 3 / 6 / 12 duct leakage testing
  • OR cores, exhaust risers, specialty systems
  • Diagnostic TAB for existing healthcare facilities

Specializing in Healthcare & Pharmaceutical Facilities

Healthcare ventilation is not standard TAB. AWPB has balanced over 25 million square feet of Canadian hospitals, clinics, and pharmaceutical facilities where minor airflow or pressurization errors can create real risk for patients, staff, and product integrity.

Critical Environments
  • Operating Rooms & Procedure Suites
  • ICU / NICU & critical care units
  • Airborne isolation & protective environments
  • Endoscopy & bronchoscopy areas
Labs & Pharma
  • GMP clean rooms & support spaces
  • Hospital & oncology pharmacies
  • USP 797 / 800 compounding rooms
  • Biosafety cabinets & fume hoods

Our field procedures align with CSA Z317.2 and current infection prevention & control (IPAC) guidance. Data is recorded in a way that engineers, facility teams, and accreditation bodies can read quickly: clear room-by-room results, pressure and airflow summaries, and targeted deficiency lists tied to specific rooms and systems

Typical Healthcare TAB Scope
  1. Review design documents and sequences for critical spaces.
  2. Balance associated AHUs, VAVs, terminals, and hydronic systems.
  3. Verify room pressurization and ACH for OR/AIIR/PE rooms.
  4. Coordinate with controls/BAS teams.
  5. Issue deficiencies and performance observations.

Need to resolve a persistent pressure or IAQ problem? AWPB also provides investigative TAB for existing healthcare facilities.

 

What Design Teams Can Expect During Testing and Balancing

We provide clear, field-based feedback during testing so design teams understand how systems are performing under real operating conditions. Our role is to verify airflow (or hydronic flow), pressures, HVAC equipment performance as well as room performance against the intended targets and communicate any constraints that affect achievable results.

  1. Transparent reporting of measured values and tolerances
  2. Identification of field conditions affecting target flows and/or pressures
  3. Clear documentation to support post-TAB decisions
  4. Coordination with mechanical and controls teams during testing

Representative Projects

A sample of the healthcare, pharmaceutical, and laboratory projects AWPB has supported across Ontario and the GTA.

Trauma Center Hospital

3-Storey Patient and Office Tower

Complete air and hydronic TAB for new tower including isolation rooms and diagnostic areas.

Scope: 6 AHUs, 100+ VAVs, 4 isolation rooms.

Cancer Centre

Quarterly Clean Room Verifications

USP 797/800 compounding suite TAB, BSC airflow support, and directional airflow mapping for clean and support spaces.

Scope: 6 clean rooms, 2 BSCs, exhaust & makeup air.

Research Facility

GMP & Biosafety Rooms

Air and hydronic TAB for research labs including GMP spaces, fume hoods, and specialty exhaust risers.

Scope: 2 AHUs, 10 fume hoods, 6 dedicated exhaust risers.

About Air & Water Precision Balancing Inc.

AWPB is a fully independent, third-party testing, adjusting, and balancing firm serving the Greater Toronto Area and beyond. We focus on healthcare, pharmaceutical, laboratory, and complex commercial environments where precision and documentation are critical.

Our team brings over 80 years of combined field experience and is certified through the Associated Air Balance Council (AABC) and the Canadian Air Balance Council (CAABC). We work closely with mechanical engineers, facility managers, infection prevention teams, and commissioning providers to deliver clear, defensible reports and practical recommendations.

Based in the Greater Toronto Area AABC / CAABC Certified Firm

Start a TAB Project

Share a few details about your facility or project and we'll follow up with a focused TAB proposal.

Email

Send specs, or a brief project description.

admin@awpbgroup.com

Service Area

We serve hospitals, clinics, laboratories, pharmaceutical facilities, condominiums and commercial spaces across the Greater Toronto Area. Contact us about projects outside the GTA.

Fields marked with an asterisk are required.

Tell us what you need tested, where the project is, and any timing constraints.

Security check

Enter the five characters in the image, or listen to the same code. Letters are not case-sensitive.

Prefer email? Send your scope or specifications to admin@awpbgroup.com. Privacy policy